XP-2 Building Products Smoke Density Testing Equipment ASTM D2843 Smoke Density Tester
Place of Origin | China |
---|---|
Brand Name | DELTA TECH |
Certification | ISO9001 |
Model Number | XP-2 |
Minimum Order Quantity | 1 set ASTM D2843 Smoke Density Tester |
Price | USD1.0 |
Packaging Details | ASTM D2843 Smoke Density Tester is packed in one veneer case |
Delivery Time | 45 days |
Payment Terms | T/T, Western Union |
Supply Ability | 10 sets ASTM D2843 Smoke Density Tester per month |

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xItem Name | XP-2 Building Products Smoke Density Testing Equipment ASTM D2843 Smoke Density Tester | Function | For Building Material Smoke Density Testing |
---|---|---|---|
Application Field | Building Material | Reference Standards | ASTM D2843 |
Dimension | 800 Mm (W) X 500 Mm (D) X 1000 Mm (H) | Weight | 35kg |
Packing Mode | Veneer Case | Warranty Period | 1 Year |
Service | Installation And Commissioning Service Is Available | Safety Features | Over Temperature Protection, Emergency Stop Button |
Fuel Gas | 95% Propane Gas | Display | Digital Display |
Electrical | 230 Volts Nominal 10 Amps |
XP-2 Building Products Smoke Density Testing Equipment ASTM D2843 Smoke Density Tester
Introduction:
-
The XP-2 Smoke Density Chamber is designed and manufactured according to the ASTM D2843 standard. It is mainly used for testing building products.
-
By detecting the loss of light transmission in the test chamber, it can measure the smoke density from burning and the decomposition of building material during the test.
Features:
-
The test chamber is Teflon coating, to resist the corrosion of smoke released during burning.
-
The light source is an incandescent lamp, and the photoelectric sensor is a silicon photodiode with a cosine calibration function.
-
Color filter is equipped to filter out ultraviolet light and infrared light.
-
The gas pressure of the main burner is 256KPA, it is subjected to flame impact on the test specimen.
-
The gas pressure of the auxiliary burner is 138KPA, so it can continue to burn the molten droplets.
-
The computer and test software are equipped.
Parameters:
No. |
Item Name |
XP-2 Building Products Smoke Density Chamber |
1 |
Dimension |
800 mm (W) x 500 mm (D) x 1000 mm (H) |
2 |
Weight |
35kg (computer is not included) |
3 |
Power supply |
220V, 10A, 50Hz, |
4 |
Ambient temperature |
10 ~ 35 Centigrade |
5 |
Installation place |
Fume hood |