All Products
-
Mr. Ricky CasipeWith regards of our test instrument the’re all in Good condition. I'll purchase some instrument sooner. Thank you very much
-
Ms. Remy GalaponFrom year 2020 to 2023, we purchased more than 30 equipment from Delta Technology, they are all work well and the service from Delta Technology is also good.
-
Mr. MilanThe VLF-80 Tester is perfect and thank you.
4530F Universal Laboratory Using AAS Analyzer For Metal Elements Testing
Place of Origin | China |
---|---|
Brand Name | Delta |
Certification | ISO9001 |
Model Number | 4530F |
Minimum Order Quantity | 1 set AAS Analyzer in one order |
Price | Negotiable |
Packaging Details | 4530F AAS Analyzer packed in veneer case. |
Delivery Time | 3-7 days |
Payment Terms | Western Union, T/T, L/C |
Supply Ability | 100 set AAS Analyzer each month |

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
Description | Universal Laboratory Using AAS Analyzer For Metal Elements Testing | Usage | Laboratory Using, Measure Elements In Samples |
---|---|---|---|
Elements Can Be Measured | Most Of Metal Elements | Sample Quantity | 8 Samples In One Test |
Control Method | Computer Control | Wavelength Range | 190 – 900nm |
Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm | Grating | 1800 Lines/mm |
Inflamer | All-metal Titanium Burner | Atomizer | Effective Glass Atomizer |
Size | 700mm×550mm×450mm | Weight | 75kg |
Product Description
4530F Universal Laboratory Using AAS Analyzer For Metal Elements Testing
Features:
- Complete automatic controlling system;
- Advanced graphite furnace temperature controlling technology;
- Safe, reliable and convenient flame system;
- Multi-functional software workstation;
- Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
- Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
- Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
- Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
- Fully automated wavelength scanning and peak searching;
- Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
- Deuterium lamp and self-absorption background regulation;
- Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
- Measuring method: flame absorption method and emission method;
- Result printing: parameter printing, data result printing and diagram printing;
Specifications:
Item Name | 4530F Universal Laboratory Using AAS Analyzer For Metal Elements Testing |
Wavelength range | 190 – 900nm |
Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | Eight lamps |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
Flame System:
Acetylene air burner | 100mm |
Nitrous oxide acetylene flame head | 50mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
Graphite Furnace:
The highest temperature | 3000℃ |
The largest temperature rising speed | ≥2000℃/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection |
Protection | Low air pressure alarm, low cooling water flow alarm |
Power source and power | 220V±22V AC 7000W |