Mr. Ricky CasipeWith regards of our test instrument the’re all in Good condition. I'll purchase some instrument sooner. Thank you very much
-
Ms. Remy GalaponFrom year 2020 to 2023, we purchased more than 30 equipment from Delta Technology, they are all work well and the service from Delta Technology is also good.
-
Mr. MilanThe VLF-80 Tester is perfect and thank you.
High Precision Atomic Absorption Spectrophotometer AAS Analyzer
Place of Origin | China |
---|---|
Brand Name | LAB TECH |
Certification | ISO9001 |
Model Number | AAS |
Minimum Order Quantity | 1 set AAS Analyzer in one order |
Price | Negotiable |
Packaging Details | AAS Analyzer packed in veneer case. |
Delivery Time | 3-10 days |
Payment Terms | Western Union, T/T, L/C |
Supply Ability | 100 sets each month |

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xFeatures | Safe, Reliable And Convenient Flame System | Description | High Precision Atomic Absorption Spectrophotometer AAS Analyzer |
---|---|---|---|
Function | Measure Concentration Of Elements In Samples | Control Method | Build-in Computer Data Processing |
Wavelength Range | 190 – 900nm | Spectral Bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Lamp Stand | 2 Lamps | Grating | 1800 Lines/mm |
Dimension | 700mm×550mm×450mm | Weight | 75kg |
Atomic Absorption Spectrophotometer AAS Analyzer
Features:
- Build-in computer data processing and LCD
- Good basic line stability
- High precision of measurement
- Optical path of high energy
- Long-life and anti-corrosive atomization system
- Multi-functional analysis mode
- Safe and reliable gas path system
Specifications:
Working spectral range | 190-900nm |
Wavelength accuracy | ≤ ±0.5nm |
Wavelength repeatability | ≤ 0.3nm (single direction) |
Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base line stability | ±0.004Abs/30min |
Characteristic concentration of copper | ≤ 0.04mg/ml/1% |
Detection limit of copper | ≤0.008mg/ml |
Background calibration ability | Greater than 30 times |
Standby Interface | RS 232 |
Instrument power supply | 220V, 3A, 50Hz |
Complete set of accessories:
Light-source system
Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current
Optical system
Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm
Flame atomization system
Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.
Signal processing
Absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.