KFZ Power Transformer Excitating Current, Capacity, Load Loss Tester

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xFeatures | Small In Volume, Light In Weight, Dual, Low Price | Item Name | KFZ Power Transformer Excitating Current, Capacity, Load Loss Tester |
---|---|---|---|
Functions | Power Transformer Excitating Current, Capacity, Load Loss Testing | Power Supply | AC220V ± 10%, 50Hz |
Warranty | One Year | Service | OEM Service Is Available |
Size | 49*31*25cm | Weight | 8kg |
Display | Digital Display | Language | English |
OEM Service | Free Of Charge |
KFZ-I Power Transformer Capacity, Load and No Load Loss Tester
Introduction:
- Power transformers an important electrical equipment, and their safe and reliable operation is extremely important for power systems.
- After the impact of a short-circuit current, the transformer winding deformation test is very important.
- To short-circuit the low-voltage winding side of the transformer and apply a low voltage of the operating frequency (50Hz or 60Hz normally) to the high-voltage winding side of the transformer, the short-circuit impedance method measures the short-circuit impedance of the operating frequency.
- The test result is mainly leakage reactance component, determined by the geometry of the winding.
- The change of the transformer winding structure will cause changes in the transformer leakage reactance, resulting in transformer short circuit impedance numerical changes.
- KFZ Power Transformer Excitation Current, Capacity, Load Loss Tester follows the national power industry standards DLT 1093-2008, and can be used for IEC60076-5-2006.
- KFZ Power Transformer Excitation Current, Capacity, and Load Loss Tester can also be used for generator rotor AC impedance test, transformer load, and no load loss test.
Specifications:
-
Using six channels of AD chip of 16 bits;
-
With a 7-inch LCD touch screen which the brightness can be adjusted;
-
With a thermal printer the print thick can be adjusted;
-
It could store fifty groups of SCI data and thirty groups of GAI data, which could be read to the current screen or uploaded to the PC;
-
With PC software using which we could upload data, test, analyze data, print data, or create Word document;
-
Using USB2.0 to connect to the device;
-
Tester dimension: 49*31*25cm;
-
Weight: 8.0KG;
-
Power: AC220V±10%, (50 or 60)HZ ;
1 | Working power | Input voltage | 185Vac~250Vac |
Allowable input voltage | 85Vac~264Vac | ||
Frequency | 50/60Hz | ||
Allowable frequency | 45Hz~65Hz | ||
Input power | 40VA | ||
2 | AC voltage | Range | 10~650V |
Resolution | 0.001V | ||
Accuracy | 0.2%±0.001V | ||
3 | AC Current | Range | 0.5~60A |
Resolution | 0.001A | ||
Accuracy | 0.2%±0.001A | ||
4 | Frequency | Range | 45Hz~65Hz |
Resolution | 0.001Hz | ||
Accuracy | 0.2%±0.001Hz | ||
5 | Power | Range | 0~39kW |
Resolution | 0.001kW | ||
Accuracy | <±0.5% | ||
6 | Capacity test range | 10kV Dry type transformer | 30kVA~3150kVA |
10kV Oil immersed transformer | 30kVA~3150kVA | ||
35kV Oil immersed transformer | 50kVA~31500kVA | ||
20kV Dry type transformer | 50kVA~2500kVA | ||
35kV Dry type transformer | 50kVA~2000kVA | ||
7 | Environment | Operating temperature | -10℃~+50℃ |
Storage temperature | -25℃~+70℃ | ||
Relative humidity | 5%~95% | ||
8 | Dimension | 40cm*30cm*22cm | |
9 | Weight | ≈8kg (Excluding accessories) |